One test case
What a test case looks like on the page
Every case has the same card, whoever runs it. An engineer who has never seen the bench can execute it from the card alone, and the vendor can repeat it in their own lab and get the same number.
Four rules for the pass criterion, applied to every case in the plan
- A number
- Not «acceptable latency» but «p99 ≤ 12 µs». If the SLA has no number yet, we derive one from the capacity plan and mark it as derived.
- A load
- Every criterion names the load it holds at: percent of line rate, sessions, routes, tunnels. Idle results are recorded but never count.
- A clock
- Sustain time and sampling interval are in the case. 300 s of sustain and a 2 s sample is the default for performance cases.
- An evidence list
- What proves the result: generator statistics, device counters, captures, console log. The report is incomplete until all of it is attached.
TC-07
Performance
Pass criterion
Latency under 70% load with 9000-byte frames
- Objective
- Confirm that storage traffic keeps its latency budget on the core switch while the uplinks carry the nightly peak
- Traffic
- Profile P2 (storage 41%, HTTPS 27%, video 18%, voice 6%, other 8%), 9000-byte frames on the storage share, ramp 60 s, sustain 300 s at 70% of line rate on all 32 ports
- KPIs
- Latency p50, p99 and max per port pair, frame loss, sampled every 2 s
- Pass criterion
- p99 ≤ 12 µs and loss 0 on every port pair for the full 300 s. One excursion above 12 µs is a pass with a note; loss is a fail.
- Evidence
- Generator latency histogram per pair, switch interface counters before and after, a capture of 60 s on two pairs