Your device, our lab, a report with the numbers

TEST4NET tests network and security equipment for vendors, operators, integrators and banks. You ship the box or upload the VM. We write the test plan, run it in CloudLAB on 1G to 100G ports and 200 Gbit/s and more of application traffic, and return a report with every measured value. The test plan and the quote come back within 1–3 business days of the first call.

Who comes to us

Three situations we meet most often

The device and the question differ. The way out is the same: an independent test with a written plan, and a report you can hand to procurement, to the board or to the vendor.

Vendors and product teams

The datasheet needs an independent number

Customers and RFPs ask for proof that is not your own slide. We run RFC 2544, RFC 2889 and RFC 9411 benchmarks, conformance and interoperability tests, and you get a third-party report to attach to the tender.

Typical project: 2–4 weeksRequest a test plan for this
NGFW throughput, Gbit/s Same box, same traffic mix Datasheet: 40 20 4031146 85% less with everything on DatasheetFirewall only+ IPS+ app control+ TLS inspection
Typical NGFW. The datasheet figure is measured with inspection off. With IPS, application control and TLS inspection on, 6 of 40 Gbit/s remain.
Operators and integrators

Two boxes, one tender, no lab of your own

Both candidates go through the same traffic, the same frame sizes and the same failure scenarios in CloudLAB. The comparison table decides the purchase instead of the better sales deck.

Typical project: 2–3 weeks per pairRequest a test plan for this
Two 100G edge routers, the same 8 ports Metric Candidate A Candidate B Throughput 64 B, line rate100%100% Frame loss at 64 B0.02%0 Latency 1518 B, 50% load4.1 µs3.9 µs BGP convergence, 1M routes1.1 s3.5 s Decision: B at the DC edge, A where the route table is large
Both candidates on the same 8 ports, the same frame sizes and the same route table. One table instead of two sales decks.
Enterprise and banks

An upgrade without a Monday morning outage

The new platform is checked before production: failover time under load, session capacity with your policy, the features you plan to switch on. Problems are fixed with the vendor while the old platform still runs.

Typical project: 1–3 weeksRequest a test plan for this
Firewall cluster failover, 1M sessions, 4,000 rules Promised: under 1 s 0 s1 s2 s3 s Before 1.8 s After the fix 0.7 s 3 of 4,000 rules behaved differently on the new version, fixed before cut-over
Failover of a firewall cluster under 1 million sessions: promised under 1 s, measured 1.8 s, 0.7 s after the vendor's fix.

How a project runs

From the first call to the report in 4 steps

Every project has a written test plan before anything is connected. That is the document your manager approves and procurement files.

  1. 1 Day 0

    Brief

    A 30–60 minute call. You describe the device, the question and the deadline. NDA first if you need one.

  2. 2 1–3 business days

    Test plan and quote

    Scope of work: tests, traffic profiles, pass criteria, tools, schedule and price. One document, ready for approval.

  3. 3 From 1 week

    Test run in CloudLAB

    You ship the box or upload the VM. Your engineers watch the sessions in a browser. Daily notes on what passed and what did not.

  4. 4 3 days after the run

    Report and debrief

    Every measured value, pass/fail per test, raw files and configs. A call to walk through the results. A retest after a fix is part of the scope.

What you hold at the end

  • Test planScope of work with pass criteria. Forward it to procurement as is.
  • Raw resultsGenerator exports, device configs, logs and captures for your own review.
  • ReportMethod, setup, tables and charts, pass/fail per test, the tool behind each number.
  • Debrief and retestA results call with the engineer who ran the tests. A retest after the fix.

A retest after a fix is part of the scope, so the report ends with a pass, not with a list of open items.

What we test

8 services, each with a written method and a pass criterion

Most projects combine 2 or 3 of them. The test plan says which ones and why.

01

Load and performance testing

Throughput, sessions, latency and loss up to and past the rated limit. You learn where the device really stops.

  • RFC 2544 and RFC 2889 on 1G–100G ports
  • RFC 9411 with inspection features on
  • Stateful application mix, 200 Gbit/s and more
From 1 weekHow we test it
02

Functional and conformance testing

Features against the specification, protocol behaviour against the RFC, with evidence for each item.

  • BGP, OSPF, IS-IS, MPLS, EVPN, VXLAN
  • Checklists from your RFP or the vendor's datasheet
  • Pass/fail per item with captures
From 2 weeksRequest this test
03

Interoperability testing

Multi-vendor pairs and chains on the bench before they meet in production.

  • Routing, switching and security vendors side by side
  • Failover and convergence between vendors
  • Your configs, your software versions
04

Security and resilience testing

NGFW, IPS and VPN efficacy and performance with threats on the wire. DDoS testing is out of scope.

  • Attack and malware sets with application traffic
  • TLS inspection at scale
  • Failover, HA and policy limits
From 2 weeksRequest this test
05

Test plan and methodology design

What to test, how, on which traffic and what counts as a pass. For your own lab or for acceptance tests with a vendor.

  • Acceptance test plans for tenders
  • Traffic profiles from your real network
  • Reviewed by an engineer with 20 years in test labs
06

Test automation and CI/CD

A regression suite that runs on every software release of the device, with a report your team reads in 5 minutes.

  • Scripts for commercial generators and our own
  • Pipeline integration and result dashboards
  • Runs in CloudLAB or in your lab
From 3 weeksRequest this test
07

Training programs

Hands-on courses for your test and network engineers on real generators and real devices.

  • RFC 2544, 2889, 9411 in practice
  • Traffic profiles, test plans, reporting
  • Online in CloudLAB or on site
08

Equipment repair

Diagnostics and repair of test and network equipment that is out of vendor support.

  • Chassis, load modules, power and fans
  • Diagnostics report before any repair
  • Verification run after the repair

The bench behind the numbers

One rack, your device in it

Commercial traffic generators and our own, WAN emulators and a Wi-Fi bench share one patching field. Your device gets reserved units, KVM and serial access, or runs as a VM on our virtual capacity.

42U36U30U24U18U12U6U Traffic generator, L2-3 1G · 10G · 100G ports, RFC 2544 / 2889 Traffic generator, L4-7 and security 200 Gbit/s and more of stateful traffic application mix, TLS, attacks, malware sets WAN emulation delay · jitter · loss · shaping per link Wi-Fi bench Wi-Fi 6 clients and access points, Wi-Fi 7 in progress Automatic patching any generator port to any device port, no hands in the rack KVM, serial, power control Your device under test reserved units · shipped in, returned after the project or a VM on the virtual capacity below Virtual capacity servers for virtual appliances and cloud agents
L2-3 switching and routing
1G and 10G ports, 100GRFC 2544, RFC 2889, convergence, route scale
L4-7 applications and security
200 Gbit/s and more of stateful traffic, grows with every server we addRFC 9411, application mix, TLS, IPS efficacy, session capacity
Wi-Fi
Wi-Fi 6 clients and access points, Wi-Fi 7 in progressThroughput, client density, roaming
WAN emulation
Delay, jitter, loss and shaping per linkSD-WAN path selection, application performance over WAN
AI fabric (RoCEv2)
Lossless Ethernet checks, capacity added step by stepPFC, ECN, incast behaviour
Access for your team
Browser sessions, automatic patching, KVM, serial console, rack space, virtual machinesWatch the run, bring your own device or software

The report names the tool and the configuration behind every number. We do not base a decision on a free generator, and we never claim a tool we did not use.

Open the CloudLAB portal

Typical scenarios

What a project looks like in numbers

Three composite projects, shown the way the report shows them. The numbers are representative of what we see. Clients are under NDA and are never named.

REPORT · Operator, purchase decisionTypical scenario

Two 100G edge routers, one tender

MetricExpectedMeasured
Loss at 64 B, 8 ports0A 0.02% · B 0
BGP convergence, 1M routes< 2 sA 1.1 s · B 3.5 s

Decision on the table: B for the data-centre edge, A where the route table is large. Both vendors received the same report.

3 weeks from brief to report · 2 × 8 ports of 100G under test
REPORT · Vendor, datasheet validationTypical scenario

An NGFW before the launch

MetricExpectedMeasured
Throughput, firewall only40 Gbit/s31 Gbit/s
IPS + app control + TLS on40 Gbit/s6 Gbit/s

The vendor published per-feature numbers instead of the single big one, 2 weeks before the launch.

2 weeks test run · 38% of the datasheet figure, all features on
REPORT · Bank, production upgradeTypical scenario

A firewall cluster swap

MetricExpectedMeasured
Failover, 1M sessions< 1 s1.8 s, 0.7 s after the fix
Policy of 4,000 rulesidentical3 rules differ

Both findings were fixed with the vendor before the cut-over weekend. Retest included, 10 days in total.

10 days including the retest · 1.8 s failover, promised sub-second
  • 20 yearsof the founder in network test labs
  • 0client names on this site, NDA by default
  • 1–3 daysfrom the call to the test plan and quote
  • 8services, each with a written method

Why TEST4NET

What you get that a vendor demo never shows

Independent
We sell tests. We do not sell the boxes, so a bad number stays in the report.
20 years in test labs
Every test plan is reviewed by the founder, 20 years in network test equipment and pre-sales labs.
NDA by default
Clients are never named. Results go to you and to nobody else.
Tool named per number
The report says which generator, which version and which configuration produced each value.

By technology

Routing and switching Firewalls and NGFW SD-WAN and WAN Cloud and NFV 5G and mobile core Wi-Fi Storage and infrastructure AI fabric (RoCEv2)

By industry

Also taken: cloud infrastructure and services, web portals together with the infrastructure in front of them. Not taken: DDoS and penetration testing.

FAQ

Questions before the first call

Request a test plan
How fast can we start?

The test plan and the quote come back within 1–3 business days of the brief. The run starts as soon as the device is in the lab or the VM is uploaded, usually within 1–2 weeks of approval.

Do we have to ship hardware to Armenia?

For a physical device, yes: it goes into our rack with KVM and serial access, and we return it after the project. Virtual appliances are uploaded to the lab. If the device cannot leave your site, we discuss remote access to your lab during the brief.

What is in the report?

The setup and the method, the parameters of every test, tables and charts per frame size or per traffic profile, pass/fail against the criteria from the test plan, raw exports and configs, and a list of findings with severity. The tool behind every number is named.

How is the price formed?

Per project, from the scope of work: the number of tests, the traffic volume, the devices and the duration. There is no public price list. Projects run from 1 week to several months, and the quote comes with the test plan.

Which tools do you use?

Commercial traffic generators and WAN emulators, and our own traffic generator, which is now in beta. The test plan names the tool for every test before you approve it. We do not rent out equipment.

Can our engineers watch the tests?

Yes. CloudLAB sessions open in a browser, so your team sees the generator and the device console live. The NDA is signed before any device details are shared.

Tell us what you run and what worries you

One call, then a test plan and a quote within 1–3 business days. A scope of work your manager can approve and procurement can file.

Send the shortlist

You have the method. Now get the numbers.

Send the shortlist and the KPIs that matter. An engineer replies within one business day with a test plan draft and a quote.