title: ITU-T Y.1564 service activation testing | TEST4NET
description: "Y.1564 (EtherSAM) methodology: step load to CIR, EIR and policing, then all services at CIR for 15 min to 24 h. IR, FTD, FDV, FLR, availability per SLA."
---

[Skip to content](https://test4net.com/methodologies/y-1564#main-content)

[![TEST4NET](https://test4net.com/hubfs/test4net-logo-fixed-2.svg)](https://test4net.com/?hsLang=en)

- Services
- Products
- Resources
- Company

[News](https://test4net.com/news?hsLang=en) [Login](https://lab.test4net.com) [Support](https://test4net.com/support?hsLang=en)

What we test

By technology

Industries

[Load & Performance Testing Throughput, sessions and latency up to and past the rated limit](https://test4net.com/services/load-performance-testing?hsLang=en) [Functional & Conformance Testing Features against the spec, RFC compliance with evidence](https://test4net.com/services/functional-conformance-testing?hsLang=en) [Interoperability Testing Multi-vendor behaviour, before it reaches production](https://test4net.com/services#interop) [Security & Resilience Testing NGFW, IPS and VPN efficacy and performance with threats on the wire](https://test4net.com/services/security-resilience-testing?hsLang=en) [Test Plan & Methodology Design What to test, how, and what counts as a pass](https://test4net.com/services/test-plan-design?hsLang=en) [Test Automation & CI/CD Regression suites wired into your release pipeline](https://test4net.com/services#automation) [Training Programs Hands-on courses for your test engineers](https://test4net.com/services#training) [Equipment Repair Diagnostics and repair of test equipment](https://test4net.com/services#repair) [All services](https://test4net.com/services?hsLang=en)

[Routing & Switching RFC 2544 and RFC 2889 on real ports, 1G to 100G](https://test4net.com/solutions/routing-switching?hsLang=en) [Firewalls & NGFW RFC 9411 throughput with inspection switched on](https://test4net.com/solutions/firewalls-ngfw?hsLang=en)

 SD-WAN & WAN Path selection and QoS under emulated WAN conditions

 Cloud & NFV Virtual appliances and cloud services under load

 5G & Mobile Core Transport and core functions under subscriber traffic

 Wi-Fi Wi-Fi 6 clients and access points, Wi-Fi 7 in progress

 Storage & Infrastructure Storage networks and servers under realistic I/O 

[AI / Switching Fabric (RoCEv2) Lossless Ethernet for GPU clusters: PFC, ECN, fabric load](https://test4net.com/solutions/ai-fabric-rocev2?hsLang=en)  All technologies

[Telecom Operators Pre-deployment acceptance and vendor comparison](https://test4net.com/solutions/industries#telecom) [Network & Security Vendors Independent validation of your product claims](https://test4net.com/solutions/industries#vendors) [System Integrators Proof for the customer before the rollout](https://test4net.com/solutions/industries#integrators) [Enterprise & Banks Upgrades and new platforms checked before production](https://test4net.com/solutions/industries#enterprise) [All industries](https://test4net.com/solutions/industries?hsLang=en)

Not sure where to start?

Test plan and quote in 1–3 business days

Tell us what you run and what worries you. We propose the tests, tools and timeline.

[Request a test plan](https://test4net.com/contacts?hsLang=en)

CloudLAB

[How It Works Pick a scenario, run it in the live lab, get the report](https://test4net.com/cloudlab#how) [Equipment & Capabilities L2-3 to 100G, L4-7 past 200G, Wi-Fi, WAN emulation](https://test4net.com/cloudlab#equipment) [Access Plans Hourly sessions, subscriptions, dedicated racks](https://test4net.com/cloudlab/plans?hsLang=en) [Hosted DUT Testing Ship the box or upload the VM, we run the tests](https://test4net.com/cloudlab/hosted-dut?hsLang=en) [Open the CloudLAB portal](https://lab.test4net.com)

Our tools

[Traffic Generator L4-7 and security traffic past 200 Gbit/s, app mix library](https://test4net.com/products/traffic-generator?hsLang=en) [WANemu Delay, jitter, loss and bandwidth shaping per link](https://test4net.com/products/wanemu?hsLang=en) [Book a demo](https://test4net.com/contacts?hsLang=en)

New: our own test tools

Our own tools, in beta this autumn

Built in our lab, priced per gigabit. Join the beta list and see them first.

[Join the beta list](https://test4net.com/products#lead-form)

Read

Technologies / Protocols

Methodologies

[Blog Case studies, test insights and lab notes](https://test4net.com/blog?hsLang=en) [Industry News What is changing in network testing and infrastructure](https://test4net.com/news?hsLang=en) [FAQ How the lab, sessions and reports work](https://test4net.com/faq?hsLang=en) [All resources](https://test4net.com/resources?hsLang=en)

 BGP Route exchange, policy and convergence

 OSPF & IS-IS IGP adjacency, flooding and SPF timing

 MPLS & SR LDP, RSVP‑TE and SR‑MPLS label paths

 EVPN / VXLAN Overlay fabrics, MAC/IP routes, multi-homing

 IPsec & IKEv2 Tunnel setup, rekeying and throughput

 TLS / HTTPS Handshakes, cipher suites and inspection

 RoCEv2 Lossless Ethernet, PFC and ECN for AI fabrics

 Wi-Fi 6 / 6E / 7 802.11ax/be, OFDMA, MLO and roaming 

 All protocols

[RFC 2544 Throughput, latency, frame loss and back-to-back](https://test4net.com/methodologies/rfc-2544?hsLang=en) [RFC 2889 LAN switch benchmarking: forwarding, MAC learning, congestion](https://test4net.com/methodologies/rfc-2889?hsLang=en) [RFC 9411 / RFC 3511 Firewall and NGFW performance benchmarking](https://test4net.com/methodologies/rfc-9411-rfc-3511?hsLang=en) [RFC 6349 TCP throughput and buffer delay testing](https://test4net.com/methodologies/rfc-6349?hsLang=en)

 RFC 5180 IPv6 benchmarking methodology 

[ITU-T Y.1564 Ethernet service activation: CIR, EIR, KPIs per service](https://test4net.com/methodologies/y-1564?hsLang=en)

 ITU-T Y.1731 Ethernet OAM: delay, jitter, loss and SLA monitoring

 TR-398 Wi-Fi in-premises performance test plan 

[All methodologies](https://test4net.com/methodologies?hsLang=en)

Read

[Case studies, test insights and lab notes Blog](https://test4net.com/blog?hsLang=en) [What is changing in network testing and infrastructure Industry News](https://test4net.com/news?hsLang=en) [How the lab, sessions and reports work FAQ](https://test4net.com/faq?hsLang=en)

[About Us Independent lab in Armenia, team and history](https://test4net.com/about?hsLang=en) [Why TEST4NET What you get that vendor slides never show](https://test4net.com/why-test4net?hsLang=en) [Lab & Certifications Bench capacity, methods and the standards we test against](https://test4net.com/lab?hsLang=en) [Partners Test tool vendors and IT partners we work with](https://test4net.com/partners?hsLang=en) [Contacts Talk to an engineer, not a sales bot](https://test4net.com/contacts?hsLang=en)

[Support portal](https://test4net.com/support?hsLang=en)

- Services
  
  What we test
  
  [Load & Performance Testing](https://test4net.com/services/load-performance-testing?hsLang=en) [Functional & Conformance Testing](https://test4net.com/services/functional-conformance-testing?hsLang=en) [Interoperability Testing](https://test4net.com/services#interop) [Security & Resilience Testing](https://test4net.com/services/security-resilience-testing?hsLang=en) [Test Plan & Methodology Design](https://test4net.com/services/test-plan-design?hsLang=en) [Test Automation & CI/CD](https://test4net.com/services#automation) [Training Programs](https://test4net.com/services#training) [Equipment Repair](https://test4net.com/services#repair) [All services](https://test4net.com/services?hsLang=en)
  
  By technology
  
  [Routing & Switching](https://test4net.com/solutions/routing-switching?hsLang=en) [Firewalls & NGFW](https://test4net.com/solutions/firewalls-ngfw?hsLang=en)  SD-WAN & WAN  Cloud & NFV  5G & Mobile Core  Wi-Fi  Storage & Infrastructure [AI / Switching Fabric (RoCEv2)](https://test4net.com/solutions/ai-fabric-rocev2?hsLang=en)  All technologies
  
  Industries
  
  [Telecom Operators](https://test4net.com/solutions/industries#telecom) [Network & Security Vendors](https://test4net.com/solutions/industries#vendors) [System Integrators](https://test4net.com/solutions/industries#integrators) [Enterprise & Banks](https://test4net.com/solutions/industries#enterprise) [All industries](https://test4net.com/solutions/industries?hsLang=en)
  
  [Not sure where to start? Test plan and quote in 1–3 business days](https://test4net.com/contacts?hsLang=en)
- Products
  
  CloudLAB
  
  [How It Works](https://test4net.com/cloudlab#how) [Equipment & Capabilities](https://test4net.com/cloudlab#equipment) [Access Plans](https://test4net.com/cloudlab/plans?hsLang=en) [Hosted DUT Testing](https://test4net.com/cloudlab/hosted-dut?hsLang=en) [Open the CloudLAB portal](https://lab.test4net.com)
  
  Our tools
  
  [Traffic Generator](https://test4net.com/products/traffic-generator?hsLang=en) [WANemu](https://test4net.com/products/wanemu?hsLang=en) [Book a demo](https://test4net.com/contacts?hsLang=en)
  
  [New: our own test tools Our own tools, in beta this autumn](https://test4net.com/products#lead-form)
- Resources
  
  Read
  
  [Blog](https://test4net.com/blog?hsLang=en) [Industry News](https://test4net.com/news?hsLang=en) [FAQ](https://test4net.com/faq?hsLang=en) [All resources](https://test4net.com/resources?hsLang=en)
  
  Technologies / Protocols
  
   BGP  OSPF & IS-IS  MPLS & SR  EVPN / VXLAN  IPsec & IKEv2  TLS / HTTPS  RoCEv2  Wi-Fi 6 / 6E / 7  All protocols
  
  Methodologies
  
  [RFC 2544](https://test4net.com/methodologies/rfc-2544?hsLang=en) [RFC 2889](https://test4net.com/methodologies/rfc-2889?hsLang=en) [RFC 9411 / RFC 3511](https://test4net.com/methodologies/rfc-9411-rfc-3511?hsLang=en) [RFC 6349](https://test4net.com/methodologies/rfc-6349?hsLang=en)  RFC 5180 [ITU-T Y.1564](https://test4net.com/methodologies/y-1564?hsLang=en)  ITU-T Y.1731  TR-398 [All methodologies](https://test4net.com/methodologies?hsLang=en)
  
  Read
  
  [Blog Case studies, test insights and lab notes](https://test4net.com/blog?hsLang=en) [Industry News What is changing in network testing and infrastructure](https://test4net.com/news?hsLang=en) [FAQ How the lab, sessions and reports work](https://test4net.com/faq?hsLang=en)
- Company
  
  [About Us](https://test4net.com/about?hsLang=en) [Why TEST4NET](https://test4net.com/why-test4net?hsLang=en) [Lab & Certifications](https://test4net.com/lab?hsLang=en) [Partners](https://test4net.com/partners?hsLang=en) [Contacts](https://test4net.com/contacts?hsLang=en)

[News](https://test4net.com/news?hsLang=en) [Login](https://lab.test4net.com) [Support](https://test4net.com/support?hsLang=en)

Methodology · Carrier Ethernet turn-up

# ITU-T Y.1564: every EVC on the circuit, checked against its SLA before the first customer frame

Y.1564 (EtherSAM) activates an Ethernet circuit in two passes. The configuration test steps each service to 25, 50, 75 and 100 % of its CIR, then to CIR + EIR and above it to prove the policer. The performance test runs all services at CIR together for 15 minutes, 2 hours or 24 hours and records IR, FTD, FDV, FLR and availability per service against the SLA thresholds. A 1 GbE UNI with three services takes under 20 minutes to configure and one long run to sign off.

- Two tests in one run: configuration service by service, then performance with every service at CIR at the same time
- Six steps per service: 25, 50, 75 and 100 % of CIR, CIR + EIR, and a policing step above the line
- Five metrics per service per second: IR, FTD, FDV, FLR and availability, each with its own pass threshold from the SLA

[Get a Y.1564 test plan](https://test4net.com/methodologies/y-1564#lead-form) [Jump to the six steps](https://test4net.com/methodologies/y-1564#tests)

SERVICE CONFIGURATION TEST IR PER STEP · Y.1564 §8.1 STEPS TO CIR CIR + EIR OFFERED ABOVE THE LINE, POLICED CIR + EIR CIR 25% 50% 75% 100% +EIR +25% STEP 1 STEP 2 STEP 3 STEP 4 EIR POLICING Four steps up, one step over the line, then the long run

Configuration test of one service: four steps to CIR, one step with EIR, one step above the line to prove policing

Where it fits

## Turn-up of a circuit that already carries an SLA

RFC 2544 proves a device. Y.1564 proves a delivered service, with the numbers the contract names, in a fraction of the time

### Carrier Ethernet hand-over

E-Line and E-LAN services from a provider or a wholesale partner, before the customer is switched on. The report is the acceptance document for both sides

### Several classes on one port

Voice, video and data on one UNI, each with its own CIR, EIR and thresholds. Y.1564 loads them together, the way the customer will

### After a change, before the ticket

New policer, new QoS map, new path in the aggregation. A two-hour run shows whether the SLA still holds, with the same figures as at turn-up

Test bed

## Generator on one side, loopback or a second unit on the other

The circuit sits between two UNIs. Our bench generates and analyses every service at once; the far end returns the frames or measures them on its own clock

GENERATOR · ANALYSER · SITE A TX + RX PER SERVICE · ONE CLOCK ONE STREAM PER SERVICE VLAN + PCP or DSCP as the SLA marks it EMIX: 64 · 128 · 512 · 1024 · 1518 B Step load to CIR, then CIR + EIR Sequence number + timestamp per frame GREEN AND YELLOW FRAMES COUNTED APART UNI A 3 SERVICES NETWORK UNDER TEST EVERY HOP, EVERY POLICER ON THE PATH EVC 1 · VOICE · CoS 5CIR 20 M EVC 2 · VIDEO · CoS 3CIR 100 M EVC 3 · DATA · CoS 0CIR 500 M + EIR 200 M ONE CIRCUIT · THREE CLASSES · ONE RUN COLOUR-AWARE 802.1Q PCP · DSCP CBS · EBS BURSTS 1G · 10G · 100G UNI GPS OR PTP FOR ONE-WAY UNI B RETURNED FAR END · SITE B LOOPBACK, OR A SECOND UNIT WHAT THE FAR END GIVES Loopback: MAC swap, round-trip FTD Second unit: one-way FTD and FDV Counters per service, per colour Both directions when the SLA is two-way IR · FTD · FDV · FLR · AVAILABILITY BED FIRST, NETWORK SECOND generator looped on itself through the same optics and cables: 100% of CIR + EIR, zero loss, FDV under 10 µs, before the circuit is plugged in

### Generator and analyser

One stream per service with its VLAN, PCP or DSCP marking, a sequence number and a timestamp in every frame. EMIX frame sizes by default; a fixed size when the SLA asks for it

### Network under test

UNI to UNI across every hop and every policer of the provider. The bed is first looped on itself through the same optics: full rate, zero loss, before the circuit is plugged in

### Far end

A loopback with MAC swap gives round-trip FTD and all counters. A second unit with GPS or PTP sync gives one-way delay and jitter, and both directions at once

### Rates we run

1 GbE, 10 GbE and 100 GbE UNIs. For 100G services the step load and the long run go at line rate; the limit is the far end, so we agree the loopback type up front

Parameters

## What is fixed before the run

Y.1564 leaves the SLA numbers to the contract and the duration to the parties. The plan lists each of them, with the value we use when the contract is silent

| Parameter | Our default | Allowed | Why it matters |
| --- | --- | --- | --- |
| CIR per service | From the SLA | Any, up to line rate | The rate the provider commits to; the step load ends here and the long run stays here |
| EIR per service | From the SLA, 0 if absent | 0 to line rate minus CIR | Excess traffic the network may carry; frames above CIR are yellow and may be dropped without a fail |
| Step load | 25, 50, 75, 100 % of CIR | Any list of 2 or more steps | Shows at what load the shaper or policer starts to bite, before the full-rate step |
| Step time | 30 s | 10 s to 60 s | Long enough for the policer bucket to settle and for FDV to be sampled; short enough to keep the test under half an hour |
| Frame sizes | EMIX: 64, 128, 512, 1024, 1518 B | Any list, or one fixed size | Real traffic is mixed; a single size hides shaper behaviour at small frames |
| Performance run | 2 h | 15 min, 2 h, 24 h | Short runs catch configuration faults; long runs catch congestion from other customers and the daily cycle |
| Colour mode | Colour-aware when EIR \> 0 | Colour-blind or colour-aware | Decides whether yellow frames count toward FLR; a colour-blind run on a colour-aware network fails the policing step |
| Pass thresholds | FLR, FTD, FDV, availability from the SLA | Per service, per metric | Every metric at every step is compared to its threshold; one miss marks the service failed and the run goes on |

Defaults follow the Y.1564 recommendation and the MEF 10 service attributes. When the contract names a value, the contract wins

### Always in our runs

- Both tests, configuration then performance (§8)
- Every service of the circuit in one run (§6)
- Colour-aware marking when the SLA has an EIR (§7.1)
- Policing step above CIR + EIR (§8.1.2)
- Counters from both ends, per colour
- Loopback pre-test of the bed

Both tests in order, every service of the circuit, colour-aware marking where there is an EIR, a policing step above the line, counters from both ends. This is what makes the result an activation and not a demo.

### Agreed per circuit

- Performance run 15 min, 2 h or 24 h (§8.2)
- Round trip by loopback or one-way with sync
- Frame size list: EMIX or a fixed size
- Step count and step time (§8.1.1)
- CBS and EBS burst test (§8.1.3)
- Both directions, or the direction in the SLA

Run length, direction, frame sizes, step count and burst tests are set in the plan with you. Each one changes how long the run takes and what the report can claim.

Inside the method

## Six steps per service, then the long run together

Y.1564 defines a configuration test and a performance test. The first goes EVC by EVC, the second loads all of them at once

1. 8.1.1Configuration
   
   ### Step load to CIR
   
   Each service alone, at 25, 50, 75 and 100 % of its CIR, one step time per level. IR must equal the offered rate at every step and FTD, FDV and FLR must stay inside the SLA. A shaper set too low shows up as IR below offered at the 100 % step.
   
   §8.1.1 · per service · 4 × step time
2. 8.1.1Configuration
   
   ### CIR + EIR
   
   Offered rate rises to CIR + EIR. Green frames must still arrive without loss; yellow frames may be dropped and are counted on their own. In colour-blind mode the network only has to pass at least the CIR.
   
   §8.1.1 · per service · 1 × step time
3. 8.1.2Configuration
   
   ### Traffic policing
   
   Offered rate goes 25 % above CIR + EIR. The policer must cut the received rate back to CIR + EIR within a tolerance, with no loss among green frames. A policer that passes everything fails here, and so does one that drops green.
   
   §8.1.2 · per service · 1 × step time
4. 8.1.3Configuration
   
   ### CBS and EBS bursts
   
   Bursts of the committed and excess burst sizes on top of the CIR. The network must absorb a CBS burst without loss and an EBS burst without dropping green. Optional in the recommendation; we run it when the SLA names burst sizes.
   
   §8.1.3 · per service · when agreed
5. 8.2Performance
   
   ### All services at CIR
   
   Every service of the circuit at its CIR at the same time, for the agreed length. IR, FTD, FDV and FLR are sampled every second per service and compared to the thresholds; one second over the limit is recorded, a pattern of them is a fail.
   
   §8.2 · all services · 15 min, 2 h or 24 h
6. 8.2Performance
   
   ### Availability
   
   Each second of the long run is available or unavailable by its FLR, availability per ITU-T Y.1563, counted in 1 s intervals. The share of available seconds per service goes against the SLA figure, typically 99.95 % or better.
   
   §8.2 · all services · same run

Procedure

## From the plan to the signature

The whole sequence for a circuit with three services on a 1 GbE UNI fits in a working day, most of it the long run

1. 00
   
   ### Test plan
   
   Services, CIR, EIR, colour mode, frame sizes, run length and every threshold in one table, signed off by both sides before anything is plugged in
2. 01
   
   ### Bed check
   
   Generator looped on itself through the test optics and cables: CIR + EIR of every service, zero loss, FDV under 10 µs. The circuit is connected only after this passes
3. 02
   
   ### Configuration test
   
   Service by service: four steps to CIR, the EIR step, the policing step, bursts when agreed. A failed step is reported at once so the configuration can be fixed and the step rerun
4. 03
   
   ### Performance test
   
   All services at CIR together for the agreed time, counters per service per second from both ends. A run that shows a fault is kept, the time series is the evidence
5. 04
   
   ### Report and hand-over
   
   Pass or fail per service and per metric, with the one-second series and the raw counters attached. A failed service comes with the step and the minute where it went wrong

ONE RUN · 3 SERVICES · Y.1564 §8 CONFIGURATION FIRST, THEN PERFORMANCE · EVERY KPI AT EVERY STEP SERVICE CONFIGURATION TEST · ONE SERVICE AT A TIME 6 STEPS × 3 SERVICES · 10 s TO 60 s A STEP EVC 1 · VOICE EVC 2 · VIDEO EVC 3 · DATA 25 · 50 · 75 · 100% CIR +EIR · POLICING same six steps same six steps SERVICE PERFORMANCE TEST ALL AT CIR, TOGETHER EVC 1 EVC 2 EVC 3 CIR 20 M · FLR, FTD, FDV sampled every second CIR 100 M · availability counted in 1 s intervals CIR 500 M · 15 min, 2 h or 24 h, as agreed IR ≥ CIR AT STEP 4 = SHAPING IS RIGHT IR ≤ CIR + EIR UNDER POLICING = THE POLICER WORKS FLR OVER THE SLA IN THE LONG RUN = NOT READY FOR TRAFFIC

One run, three services: six steps each in turn, then the long run together. The pass rules are the same at every step

### Pass rules we apply

- IR ≥ CIR
  
  At the 100 % step and through the long run the received rate per service equals the committed rate, within the tolerance of the frame size mix
- 0 green loss
  
  No green frame lost at any step of the configuration test, and FLR under the SLA figure in the performance test
- ≤ CIR + EIR
  
  Under policing the received rate is capped at CIR + EIR; a cap too high or too low fails the step
- FTD · FDV
  
  Delay and jitter per service inside the SLA at every step, measured on the same frames that carry the rate

### Time budget

- **Bed check**10 minutes, once per set of optics and cables
- **Configuration test**3 to 6 minutes per service with a 30 s step; three services in under 20 minutes
- **Performance test**15 minutes for a quick turn-up, 2 hours as our default, 24 hours when the SLA names a daily availability figure
- **Report**Same day for a 2 h run, the day after for 24 h

Report

## What you get at the end

A verdict per service and per metric, and the series behind it. Enough to sign the acceptance, or to send the provider to the exact minute and hop

### Per service

- IR at every step of the configuration test, offered against received
- Green and yellow frame counts at CIR + EIR and under policing
- FTD and FDV at every step: minimum, average, maximum
- FLR over the performance run and per second
- Availability: available and unavailable seconds
- Pass or fail against each SLA threshold

### Context

- Service table: VLAN, marking, CIR, EIR, CBS, EBS, colour mode
- Bed check result with the optics and cables used
- Direction of each measurement, loopback type or sync source
- Frame size list and step time
- Timestamps of every step and of the long run
- Firmware and software versions of the test units

Y.1564 · ACTIVATION REPORT 1 GbE UNI · 3 EVC · 2 h RUN 8.1EVC 1 voice · CIR 20 M, steps 8.1EVC 2 video · CIR 100 M, steps 8.1EVC 3 data · CIR 500 M + EIR 200 M 8.1EVC 3 policing at CIR + EIR + 25% 8.2EVC 1 · FLR / FTD / FDV 8.2EVC 2 · FLR / FTD / FDV 8.2EVC 3 · FLR / FTD / FDV 8.2Availability, all services 20.0 M 100.0 M 699.8 M 700.1 M 0.000% 0.001% 0.42% 100% IR at every step · FTD 4.1 ms · FDV 0.2 ms · FLR 0 IR at every step · FTD 4.3 ms · FDV 0.4 ms · FLR 0 green 500 M, yellow 199.8 M · FTD 4.6 ms offered 875 M, passed 700.1 M · policer holds FTD 4.1 ms · FDV 0.3 ms · SLA: 1% · 10 ms · 2 ms FTD 4.4 ms · FDV 0.6 ms · SLA: 0.1% · 20 ms · 5 ms loss from minute 38 · SLA 0.1% · green frames only 0 unavailable seconds in 7,200 ATTACHED SERVICE TABLE STEP GRAPHS 1 s KPI SERIES COUNTERS · PCAP Values are illustrative. Your report carries your services, your SLA thresholds and your run length.

### Attached

- One-second KPI series per service as CSV, for your own charts
- Raw counters from both ends and a PCAP of the first and last minute
- Step graphs as PNG, ready for the acceptance document

From practice

## The service that passed alone and failed in company

A 1 GbE UNI with voice, video and data. Every service passed its configuration test: steps to CIR clean, policer at the right line. In the performance test, from the 38th minute, the data service lost 0.42 % of its green frames while the other two stayed clean.

The three CIRs add up to 620 Mbit/s. The policer on the aggregation node was set to 450 Mbit/s, a figure from an earlier version of the order. Alone, no service ever reached it. Together, they did. The SLA was signed a day later, after the fix and a second run.

Y.1564 performance test on a 1 GbE E-Line, three EVCs, 2 h run

SAME CIRCUIT · FRAME LOSS RATIO · TWO TESTS CONFIGURATION TEST · EVC 3 ALONE 500 M green for 60 s per step · 0 frames lost · passed 0.00% PERFORMANCE TEST · 3 EVC TOGETHER, 2 h 620 M on the trunk from minute 38 · EVC 3 loses green frames · SLA 0.1% 0.42% POLICER ON THE AGGREGATION NODE 450 M Set at 450 M instead of 620 M for the three classes. Found before the SLA started.

Services

## How we run Y.1564 for you

On our CloudLAB bench against your equipment, or on your circuit with our units at both ends. Same plan, same report

### Turn-up of a new circuit

Plan, bed check, both tests, report. For the provider, or for the customer who wants an independent acceptance

[Order a turn-up](https://test4net.com/contacts?hsLang=en)

### Device check before deployment

Your CE or aggregation device on our bench, with the services it will carry. Policers, shapers and QoS maps proven before they go into the field

[Bring your device](https://test4net.com/contacts?hsLang=en)

### Dispute between provider and customer

One run, one report, both parties on the distribution list. The numbers are the same for everyone

[Ask for a neutral run](https://test4net.com/contacts?hsLang=en)

### Recurring checks

The same plan rerun after each change in the path, with the previous report as the baseline

[Set up a schedule](https://lab.test4net.com/)

- Report in the Y.1564 structure, step by step, service by service
- Test units chosen for the rate and the far end, from more than one vendor
- Engineers who read the SLA before the counters

### Related methodologies

- [MethodologyRFC 2544: zero-loss benchmark for switches and routers](https://test4net.com/methodologies/rfc-2544?hsLang=en)
- [MethodologyRFC 2889: forwarding, congestion and address handling of a switch](https://test4net.com/methodologies/rfc-2889?hsLang=en)
- [About usWhy TEST4NET: an independent lab and how it works](https://test4net.com/why-test4net?hsLang=en)

FAQ

## Questions we get about Y.1564

How is Y.1564 different from RFC 2544?

RFC 2544 benchmarks a device with one stream at a time and searches for the maximum throughput. Y.1564 activates a service: several services at once, at the rates in the SLA, with pass or fail per metric. A full RFC 2544 set takes hours; a Y.1564 configuration test takes minutes per service.

Do we need a second test unit at the far end?

A loopback is enough for rate, loss and round-trip delay. One-way delay and jitter, or a circuit whose two directions differ, need a second unit with GPS or PTP synchronisation. The plan says which one applies.

What does colour-aware mean in practice?

Frames within CIR are green, frames between CIR and CIR + EIR are yellow. A colour-aware network may drop yellow frames under congestion and must keep the green ones. The test unit marks and counts them separately, so a dropped yellow frame does not fail the service.

How long should the performance test run?

Fifteen minutes catches configuration errors. Two hours is our default and catches most congestion from other traffic. Twenty-four hours is needed when the SLA names a daily availability figure or when the fault is tied to a time of day.

Can you test a 100 GbE service?

Yes. The step load and the long run go at line rate. The limit is the far end: a passive loopback works, a second unit must keep up with the rate. We agree the pair before the plan is signed.

What happens when a service fails?

The run goes on and the service is marked failed with the step and the time. You fix the configuration, we rerun the configuration test of that service and then the performance test with all services. The report shows both runs.

## Test plan and quote in 1 to 3 business days

Send the service table or the SLA extract. You get the plan with every parameter and threshold, the run length and a quote for the run

[Request a Y.1564 plan](https://test4net.com/methodologies/y-1564#lead-form) [Log in to CloudLAB](https://lab.test4net.com/)

Send the shortlist

## You have the method. Now get the numbers.

Name the models and the KPIs that matter. An engineer replies within one business day with a test plan draft and a quote.

Prefer to chat? [Message an engineer on WhatsApp](https://wa.me/37491612709)

We use what you send only to answer you. See our [Privacy Policy](https://test4net.com/privacy-policy?hsLang=en).

[Send the shortlist](https://test4net.com/methodologies/y-1564#lead-form)

[![TEST4NET LLC](https://test4net.com/hubfs/test4net-logo-fixed.svg)](https://test4net.com?hsLang=en)

Independent testing and validation for telecom, information security and cloud infrastructure – real insights, not assumptions

<https://www.linkedin.com/company/test4net> <https://wa.me/37491612709> <https://t.me/TEST4NET> [mailto:sales@test4net.com](mailto:sales@test4net.com) <https://www.facebook.com/people/Test4net-LLC/61591470856077/> <https://www.youtube.com/@TEST4NET>

#### Navigate

- [Home](https://test4net.com/?hsLang=en)
- [Why TEST4NET](https://test4net.com/why-test4net?hsLang=en)
- [About us](https://test4net.com/about?hsLang=en)
- [Contact](https://test4net.com/contacts?hsLang=en)
- [Blog](https://test4net.com/blog?hsLang=en)
- [Industry News](https://test4net.com/news?hsLang=en)

#### Get in touch

Sales

[sales@test4net.com](mailto:sales@test4net.com)

Support

[support.test4net.com](https://support.test4net.com)

© 2026 TEST4NET LLC. All rights reserved.

[Privacy Policy](https://test4net.com/privacy-policy?hsLang=en) [Legal](https://test4net.com/legal?hsLang=en)

```json
{
  "@context" : "https://schema.org",
  "@id" : "https://test4net.com/#organization",
  "@type" : "Organization",
  "address" : {
    "@type" : "PostalAddress",
    "addressCountry" : "AM",
    "addressLocality" : "Yerevan",
    "postalCode" : "0033",
    "streetAddress" : "3 Hakob Hakobyan Street (Mergelyan Hub)"
  },
  "alternateName" : "TEST4NET",
  "contactPoint" : {
    "@type" : "ContactPoint",
    "availableLanguage" : [ "en", "ru", "hy" ],
    "contactType" : "sales",
    "email" : "sales@test4net.com",
    "telephone" : "+374-60-88-88-99"
  },
  "description" : "Independent, vendor-neutral lab for testing network and cybersecurity products — NGFW, WAF, IPS, DLP and SASE — and an authorized distributor of test, measurement and network infrastructure solutions.",
  "email" : "sales@test4net.com",
  "foundingDate" : "2024",
  "image" : "https://test4net.com/hubfs/og-t4n.png",
  "logo" : "https://test4net.com/hubfs/test4net-logo-fixed-2.svg",
  "name" : "TEST4NET LLC",
  "sameAs" : [ "https://www.linkedin.com/company/test4net/", "https://t.me/TEST4NET", "https://www.facebook.com/people/Test4net-LLC/61591470856077/" ],
  "telephone" : "+374-60-88-88-99",
  "url" : "https://test4net.com/"
}
```

```json
{
  "@context" : "https://schema.org",
  "@id" : "https://test4net.com/#website",
  "@type" : "WebSite",
  "inLanguage" : "en",
  "name" : "TEST4NET",
  "potentialAction" : {
    "@type" : "SearchAction",
    "query-input" : "required name=search_term_string",
    "target" : {
      "@type" : "EntryPoint",
      "urlTemplate" : "https://test4net.com/hs-search-results?term={search_term_string}"
    }
  },
  "publisher" : {
    "@id" : "https://test4net.com/#organization"
  },
  "url" : "https://test4net.com/"
}
```

```json
{
  "@context" : "https://schema.org",
  "@type" : "FAQPage",
  "mainEntity" : [ {
    "@type" : "Question",
    "acceptedAnswer" : {
      "@type" : "Answer",
      "text" : "RFC 2544 benchmarks a device with one stream at a time and searches for the maximum throughput. Y.1564 activates a service: several services at once, at the rates in the SLA, with pass or fail per metric. A full RFC 2544 set takes hours; a Y.1564 configuration test takes minutes per service."
    },
    "name" : "How is Y.1564 different from RFC 2544?"
  }, {
    "@type" : "Question",
    "acceptedAnswer" : {
      "@type" : "Answer",
      "text" : "A loopback is enough for rate, loss and round-trip delay. One-way delay and jitter, or a circuit whose two directions differ, need a second unit with GPS or PTP synchronisation. The plan says which one applies."
    },
    "name" : "Do we need a second test unit at the far end?"
  }, {
    "@type" : "Question",
    "acceptedAnswer" : {
      "@type" : "Answer",
      "text" : "Frames within CIR are green, frames between CIR and CIR + EIR are yellow. A colour-aware network may drop yellow frames under congestion and must keep the green ones. The test unit marks and counts them separately, so a dropped yellow frame does not fail the service."
    },
    "name" : "What does colour-aware mean in practice?"
  }, {
    "@type" : "Question",
    "acceptedAnswer" : {
      "@type" : "Answer",
      "text" : "Fifteen minutes catches configuration errors. Two hours is our default and catches most congestion from other traffic. Twenty-four hours is needed when the SLA names a daily availability figure or when the fault is tied to a time of day."
    },
    "name" : "How long should the performance test run?"
  }, {
    "@type" : "Question",
    "acceptedAnswer" : {
      "@type" : "Answer",
      "text" : "Yes. The step load and the long run go at line rate. The limit is the far end: a passive loopback works, a second unit must keep up with the rate. We agree the pair before the plan is signed."
    },
    "name" : "Can you test a 100 GbE service?"
  }, {
    "@type" : "Question",
    "acceptedAnswer" : {
      "@type" : "Answer",
      "text" : "The run goes on and the service is marked failed with the step and the time. You fix the configuration, we rerun the configuration test of that service and then the performance test with all services. The report shows both runs."
    },
    "name" : "What happens when a service fails?"
  } ]
}
```